- Allows console operation at extended distances of up to 200m using CAT5/5e/6 cable
- Local workstation may be connected using a suitable CAM, please click here
- Connects to your USB keyboard and mouse and VGA monitor
- Supports display resolutions of up to 1600 x 1200 @ 75m, 1024x768 @ 200m
- Power supply included
- Allows your USB keyboard, mouse and monitor to be located up to 200m away from your computer using low cost CAT5/5e cable
- Provides a convenient and secure method of remotely locating workstations and fileservers without compromising control and convenience
- Installs in minutes - no special software required
Important: This product is solely for use with the MC5, MC5-IP ans SC5 KVM Switch range. It is not a standalone KVM Extender solution. The picture above shows front and rear views of a single unit. See our range of KVM Extenders.Part No. 39357 -
Our gray plenum solid shielded Cat6 Ethernet cable is used for networking and phone infrastructure, and comes on a convenient spool. Cat6 cable is used in network applications and has been designed specifically for Gigabit Ethernet applications. They perform at high-data transfer rates, and work with ATM and gigabit speed products. Our Cat6 Ethernet cable exceeds the EIA/TIA-568-C standard. In a typical residential environment, an in-wall rated cable will suffice. However, commercial installations of cabling will have more requirements. In commercial buildings, there will be an area between floors or above office areas for heating/cooling airflow called the plenum. If an office were to catch fire, this plenum area could easily allow the spread of the fire to more floors or across the entire building. Cables that do not have a jacket rated for in wall or plenum use could actually cause the fire to become more intense. Plenum rated cables are jacketed with a fire-retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) or a fluorinated ethylene polymer (FEP) for less toxicity during a fire. If a fire gets into a plenum rated area that contains plenum rated cables and the fire spreads, the cables will not be to blame. Plenum rated cables can help prevent the spread of fires, but keep in mind that a Plenum rated cable will have no data transmission speed benefit over a non-plenum rated cable.Part No. 11X8-521NH
-
Our black plenum solid Cat6 Ethernet cable is used for networking and phone infrastructure, and comes on a a convenient spool. Cat6 Cable is used in network applications and has been designed specifically for Gigabit Ethernet applications. They perform at high-data transfer rates, and work with ATM and gigabit speed products. This particular cable is a plenum rated black solid bulk cable. The individual conductors are 23 AWG (American wire gauge) solid pure copper. Our Cat6 Ethernet cable exceeds the EIA/TIA-568-C standard. In a typical residential environment, an in-wall rated cable will suffice. However, commercial installations of cabling will have more requirements. In commercial buildings, there will be an area between floors or above office areas for heating/cooling airflow called the Plenum. If an office were to catch fire, this plenum area could easily allow the spread of the fire to more floors or across the entire building. Cables that do not have a jacket rated for in wall or plenum use could actually cause the fire to become more intense. Plenum rated cables are jacketed with a fire-retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) or a fluorinated ethylene polymer (FEP) for less toxicity during a fire. If a fire gets into a plenum rated area that contains plenum rated cables and the fire spreads, the cables will not be to blame.Part No. 11X8-522NH
-
Our orange plenum solid shielded Cat6 Ethernet cable is used for networking and phone infrastructure, and comes on a convenient spool. Cat6 cable is used in network applications and has been designed specifically for Gigabit Ethernet applications. They perform at high-data transfer rates, and work with ATM and gigabit speed products. Our Cat6 Ethernet cable exceeds the EIA/TIA-568-C standard. In a typical residential environment, an in-wall rated cable will suffice. However, commercial installations of cabling will have more requirements. In commercial buildings, there will be an area between floors or above office areas for heating/cooling airflow called the plenum. If an office were to catch fire, this plenum area could easily allow the spread of the fire to more floors or across the entire building. Cables that do not have a jacket rated for in wall or plenum use could actually cause the fire to become more intense. Plenum rated cables are jacketed with a fire-retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) or a fluorinated ethylene polymer (FEP) for less toxicity during a fire. If a fire gets into a plenum rated area that contains plenum rated cables and the fire spreads, the cables will not be to blame. Plenum rated cables can help prevent the spread of fires, but keep in mind that a Plenum rated cable will have no data transmission speed benefit over a non-plenum rated cable. Please note that due to the thickness of this cable, no male connectors will fit. This cable is intended to be punched down in a keystone jack, or into a patch panel.Part No. 11X8-531NH
-
Our green plenum solid shielded Cat6 Ethernet cable is used for networking and phone infrastructure, and comes on a convenient spool. Cat6 cable is used in network applications and has been designed specifically for Gigabit Ethernet applications. They perform at high-data transfer rates, and work with ATM and gigabit speed products. Our Cat6 Ethernet cable exceeds the EIA/TIA-568-C standard. In a typical residential environment, an in-wall rated cable will suffice. However, commercial installations of cabling will have more requirements. In commercial buildings, there will be an area between floors or above office areas for heating/cooling airflow called the plenum. If an office were to catch fire, this plenum area could easily allow the spread of the fire to more floors or across the entire building. Cables that do not have a jacket rated for in wall or plenum use could actually cause the fire to become more intense. Plenum rated cables are jacketed with a fire-retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) or a fluorinated ethylene polymer (FEP) for less toxicity during a fire. If a fire gets into a plenum rated area that contains plenum rated cables and the fire spreads, the cables will not be to blame. Plenum rated cables can help prevent the spread of fires, but keep in mind that a Plenum rated cable will have no data transmission speed benefit over a non-plenum rated cable. Please note that due to the thickness of this cable, no male connectors will fit. This cable is intended to be punched down in a keystone jack, or into a patch panel.Part No. 11X8-551NH
-
Our blue plenum solid shielded Cat6 Ethernet cable is used for networking and phone infrastructure, and comes on a convenient spool. Cat6 cable is used in network applications and has been designed specifically for Gigabit Ethernet applications. They perform at high-data transfer rates, and work with ATM and gigabit speed products. Our Cat6 Ethernet cable exceeds the EIA/TIA-568-C standard. In a typical residential environment, an in-wall rated cable will suffice. However, commercial installations of cabling will have more requirements. In commercial buildings, there will be an area between floors or above office areas for heating/cooling airflow called the plenum. If an office were to catch fire, this plenum area could easily allow the spread of the fire to more floors or across the entire building. Cables that do not have a jacket rated for in wall or plenum use could actually cause the fire to become more intense. Plenum rated cables are jacketed with a fire-retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) or a fluorinated ethylene polymer (FEP) for less toxicity during a fire. If a fire gets into a plenum rated area that contains plenum rated cables and the fire spreads, the cables will not be to blame. Plenum rated cables can help prevent the spread of fires, but keep in mind that a Plenum rated cable will have no data transmission speed benefit over a non-plenum rated cable. This cable is shielded for use in heavy electronic environments.Part No. 11X8-561NH
-
Our red plenum solid shielded Cat6 Ethernet cable is used for networking and phone infrastructure, and comes on a convenient spool. Cat6 cable is used in network applications and has been designed specifically for Gigabit Ethernet applications. They perform at high-data transfer rates, and work with ATM and gigabit speed products. Our Cat6 Ethernet cable exceeds the EIA/TIA-568-C standard. In a typical residential environment, an in-wall rated cable will suffice. However, commercial installations of cabling will have more requirements. In commercial buildings, there will be an area between floors or above office areas for heating/cooling airflow called the plenum. If an office were to catch fire, this plenum area could easily allow the spread of the fire to more floors or across the entire building. Cables that do not have a jacket rated for in wall or plenum use could actually cause the fire to become more intense. Plenum rated cables are jacketed with a fire-retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) or a fluorinated ethylene polymer (FEP) for less toxicity during a fire. If a fire gets into a plenum rated area that contains plenum rated cables and the fire spreads, the cables will not be to blame. Plenum rated cables can help prevent the spread of fires, but keep in mind that a Plenum rated cable will have no data transmission speed benefit over a non-plenum rated cable.Part No. 11X8-571NH
-
Our yellow plenum solid Cat6 Ethernet cable comes in easy to use spools. It is used for networking and phone infrastructure. Cat6 Cable is used in network applications and has been designed specifically for Gigabit Ethernet applications. They perform at high-data transfer rates, and work with ATM and gigabit speed products. This cable is a plenum rated yellow solid bulk cable. The individual conductors are 23 AWG (American wire gauge) solid pure copper. Our Cat6 Ethernet cable exceeds the EIA/TIA-568-C standard. In a typical residential environment, an in-wall rated cable will suffice. However, commercial installations of cabling will have more requirements. In commercial buildings, there will be an area between floors or above office areas for heating/cooling airflow called the Plenum. If an office were to catch fire, this plenum area could easily allow the spread of the fire to more floors or across the entire building. Cables that do not have a jacket rated for in wall or plenum use could actually cause the fire to become more intense. Plenum rated cables are jacketed with a fire-retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) or a fluorinated ethylene polymer (FEP) for less toxicity during a fire. If a fire gets into a plenum rated area that contains plenum rated cables and the fire spreads, the cables will not be to blame.Part No. 11X8-581NH
-
Rackmount Fixed Wall Mount Cabinet, 12U. This 12U Fixed Wallmount Cabinets are a cost effective solution when you need to mount equipment securely on the wall. Mounting in just minutes, our fixed wall racks have a sleek tempered glass door and removable locking side panels. Each rack has one set of fully adjustable cage-nut style rails and removable top and bottom cable slot panels, allowing easy installation of CAT5 or fiber optic cables.Part No. 61C2-11212